Product portfolio
Motors
Medium voltage motors
Our medium voltage motor is the perfect solution for demanding industrial applications. With an output of up to 700kW and a voltage of up to 6.6kV, it offers the highest reliability and efficiency.
| Feature | Specification |
|---|---|
| Frame size | 63 – 500 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 160kW – 700kW |
| Ex-certificates | ATEX, IECEx, CCC |
| Voltages | 3 kV – 6,6 kV |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| IP protection class | IP55, IP 56, IP65, IP66 |
| Cooling Type | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
Water-cooled low-voltage motor
By eliminating the fan, our water-cooled motors are the quietest in our portfolio and offer good conditions for utilizing thermal losses heat via heat exchangers.
| Feature | Specification |
|---|---|
| Frame size | 160 – 355 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 13,5 – 400 kW |
| Ex-certificates | ATEX, IECEx, CCC |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Number of poles | 2-pole, 4-pole |
| IP protection class | IP55, IP 56, IP65, IP66 |
Axial ventilated motors
For some applications, a low noise level is important. Our axially ventilated motors reduce the sound pressure level by 10dB(A) to 12dB(A) compared to radial ventilation.
| Feature | Specification |
|---|---|
| Frame size | 63 – 500 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 0,12 – 630kW |
| Ex-certificates | ATEX, IECEx, CCC |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Temperature class | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
| IP protection class | IP55, IP 56, IP65, IP66 |
Motors with externally driven axial fan
With forced ventilation, the motor is cooled by a separate forced fan motor with axial ventilation. The forced fan motor allows independent cooling.
| Feature | Specification |
|---|---|
| Frame size | 132 – 450 |
| Explosion protection | I 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 2,2 – 700 kW |
| Ex-certificates | ATEX, IECEx, CCC |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Temperature class | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
| IP protection class | IP55, IP 56, IP65, IP66 |
Motor without ventilation
With the appropriate power reduction, our low-voltage motors are also available without ventilation. If installed in air currents, the power reduction is not required.
| Feature | Specification |
|---|---|
| Frame size | 63 – 500 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 0,12 – 630kW |
| Ex-certificates | ATEX, IECEx, CCC |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Temperature class | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
| IP protection class | IP55, IP56, IP65, IP66 |
Built-on Brakes
Brakes are used to limit and regulate the rotational speed of the motor or can also be used as a holding brake for positioning conveyor belts, for example.
For sizes 71 to 160, we have developed our own brake that can be installed on both the Drive-end and the Non-Drive end. Outside of these sizes, we work with various well-known manufacturers to offer tailor-made solutions.
| Feature | Specification |
|---|---|
| Frame size | 71 – 280 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Braking torque | 4 – 1200 Nm |
| Ex-certificates | ATEX, IECEx |
| Voltages | 24 – 690 |
| Temperature class | T4 |
| IP protection class | IP55, IP56, IP65, IP66 |
Motor with built-in brake
Brakes are used wherever loads are held. Our motor with built-in flameproof enclosed brake is a more cost-effective solution with a shorter leadtime than built-in brakes.
| Feature | Specification |
|---|---|
| Frame size | 80 – 132 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Output power | 0,18 – 7,5 kW |
| Ex-certificates | ATEX, IECEx |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Temperature class | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
| IP protection class | IP55, IP 56, IP65, IP66 |
Motor with built-on Encoder
We use incremental encoders from various manufacturers for electrical position determination and motor speed control. These devices convert the input variable “speed” into an analog or digital electrical signal.
| Feature | Specification |
|---|---|
| Size | 80 – 450 |
| Explosion protection | II 2G Ex db eb IIC(B) T4 Gb, II 2G Ex db IIC(B) T4 Gb, II 2D Ex tb IIC T120°C Db |
| Power output | 0,18 – 400kW |
| Ex-certificates | ATEX, IECEx |
| Voltages | 220 – 690 V |
| Mounting Type | B3, B5, V5, V6, V1, V18, B14, B35 |
| Temperature class | 155 (F) according to 130 (B) or 180(H) according to 155 (F) |
| IP protection class | IP55, IP 56, IP65, IP66 |




















